S4 AURORA – Paramagnetic oxygen analyser

Product Description

The new S4 AURORA Paramagnetic oxygen analysers provide accurate percent measurements in combustion testing, inert atmospheres, medical and safety for humans, internal combustion engine exhausts and many more applications. With a remote software suite for control over the Internet, and an optional wireless tablet, the S4 AURORA is simple to operate. To ensure flexibility, users are able to specify their required configuration and programmable contact closures are available for gas path control. In common with all S4 analysers, the AURORA range deliver outstanding performance –  0.01% resolution and  0.1% linearity.

Optional Configuration

The new S4 AURORA Paramagnetic oxygen analysers provide accurate percent measurements in combustion testing, inert atmospheres, medical and safety for humans, internal combustion engine exhausts and many more applications. With a remote software suite for control over the Internet, and an optional wireless tablet, the S4 AURORA is simple to operate. To ensure flexibility, users are able to specify their required configuration and programmable contact closures are available for gas path control. In common with all S4 analysers, the AURORA range deliver outstanding performance –  0.01% resolution and  0.1% linearity.

Additional information

Applications

, , , , , , , , , , , , , , , , , , , , , , ,

Technology

Gases Sensed

Key Features

• Many different configurations

• Programmable contact closure for gas path control

• Wireless tablet

• Remote software suite for control over the Internet

• 0.01% O2 resolution

• 0.1% linearity

Relevant standards: 

  • EN 14789 
  • Ecodesign 
  • ARP1256D 

Documentation

➔ Datasheet

➔ Wireless Tablet User Manual

Technical Specification

DETECTOR TYPE: Paramagnetic. ‘Dumb bell’ servo driven.

RANGES:
Range A: 0-5%, 0-10%, 0-25%.
Range B: 0-100%
Range C: 95-100%

NOISE: 0.005% O2.

LINEARITY: +/- 0.1% O2

REPEATABILITY: < +/- 0.01% O2

ZERO DRIFT: <+/- 0.2% O2 per 30 days

RESPONSE TIME: < 4.5s

FLOW EFFECT: 0.05% change in reading with flow change of 0.4 l/min to 1.4 l/min into atmospheric pressure.

TEMPERATURE EFFECT:
ZERO – 0.1% O2 Change per degrees-C
SPAN – 0.05% O2 Change per degrees-C

TILT EFFECT: 0.01% O2 per degree of tilt.

EXTERNAL MAGNETIC EFFECT: A mass of soft magnetic material anywhere on the enclosure will cause less than 0.1 % O2 change in reading.

CONSTRUCTION: Wetted parts, 316 Stainless steel and Quartz

DIMENSIONS: 19” X 133.3mm X 550mm

WEIGHT: 12 Kg

POWER REQUIREMENTS: 110VAC – 250VAC or 24VDC. 70 Watts.

OUTPUTS:
0-10 volts
RS232
Ethernet (remote software is included)
Optional 4-20 mA.

GAS CALIBRATION SERVICES: Nitrogen (to set analyser zero) Oxygen in Nitrogen of appropriate concentration for calibration. Or room air.