Sample Handling

Signal’s sample handling modules and components condition gas samples in preparation for analysis.

Within the field of gas analysis much time is spent looking at the accuracy and uncertainty in the detection technique. However, without appropriate sample handling, what you are measuring could potentially bear little or no relation to your original sample.

Signal manufacture our own range of sample handling components including chillers with minimal condensate contact to limit and loss of soluble species, heated transfer lines to prevent condensation, probes to ensure representative samples are obtained, plus various filters to protect expensive and delicate analysis modules.

Heated Sample Handling Units

363 Portable Heated Sample Pump/Filter

A light duty, portable heated pump and pre-filter unit for use with single heated instruments. Provides variable inlet pressures and sample flow rates for very low sample pressures, or very long heated lines, or for pumpless measurement instruments.

361/2 Heated Pump / Filter / Dist Oven

A built-in heated pump draws sample from the pre-filtered exhaust probe. This is then distributed to two heated analysers, and a third line is fed to a cooler dryer for sample conditioning for dry gas analysers such as the Signal multi-gas PULSAR range NDIR analysers. The two filters can be switched via an external switching unit (picture shows dual channel Model 362).

346 FEF Module

The Front End Filter (FEF) module is a prefilter which is installed close to the sampling point, providing sample filtration and system integrity checking with Span gas being passed down the heated line to check for hydrocarbon ‘hang-up’.

Cooler Dryers

250 Cooler / Dryer

The 250 Portable cooler dryer removes water vapour from stack and exhaust emission gases, before analysis by ambient analysers. Errors due to water interference are removed and condensation is prevented from occurring inside the analyser.

200SM Series Cooler / Dryer

The 200SM Series of 19″ rack mounting cooler dryers remove water vapour from Stack and Exhaust Emission gases, before analysis by ambient analysers. Errors due to water  interference are removed and condensation is prevented from occurring inside the analysers. The unit is based on a solid state Peltier cooler element with a continuous peristaltic pump which removes the unwanted water.

Sample Probes

Signal Group offer a large range of sample probes for various applications. These can be Heated or Insulated. Probe material include Stainless Steel, Monel, Hastaloy and ceramic. Air purging and calibration gas inlets are some of the options available.

Heated Sample Lines

Signal Group’s Trace heated line is designed to convey hot exhaust gasses from sample points and probes to analyser, without compromising sample integrity. 1/4″ & 3/8″ tube diameter, 1m to 20m in length.