Search

320 Cutter

Product Description

The 320 Cutter provides a low cost alternative to “all in one” FIDs with a built in cutter. Housed in a portable case suitable for inline usage with portable and fixed equipment, this unit is ideal for use with the 3010 MINIFID. Two modes of operation allow a reading for either total hydrocarbons or methane only, allowing you to read a value for non-methane hydrocarbon concentration. In the methane mode the sample is directed through a heated catalyst.

Optional Configuration

The 320 Cutter provides a low cost alternative to “all in one” FIDs with a built in cutter. Housed in a portable case suitable for inline usage with portable and fixed equipment, this unit is ideal for use with the 3010 MINIFID. Two modes of operation allow a reading for either total hydrocarbons or methane only, allowing you to read a value for non-methane hydrocarbon concentration. In the methane mode the sample is directed through a heated catalyst.

This catalyst oxidises non-methane species of hydrocarbons in the sample. The THC mode bypasses this catalyst to provide a reading for total hydrocarbon. These two modes allow the der4ation of a non-methane hydrocarbon by simply deducting the methane only reading from the total hydrocarbon value. As a stand alone unit, this cutter is suitable for use with any heated FID to obtain a methane only or non-methane concentration reading.

Additional information

Applications

, , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Gas Connections

¼ Stainless Steel, 6mm

Additional Information

In the methane mode the sample is directed through a heated catalyst. This catalyst oxidises non-methane species of hydrocarbons in the sample. The THC mode bypasses this catalyst to provide a reading for total hydrocarbon. These two modes allow the derivation of a non-methane hydrocarbon by simply deducting the methane only reading from the total hydrocarbon value.

As a stand alone unit, this cutter is suitable for use with any heated FID to obtain a methane only or non-methane concentration reading.

Documentation

➔ Ancillary Equipment Brochure

➔ Datasheet

➔ User Manual

Technical Specification

CONVERTER CHAMBER: Fully heated

GAS CONTACT MATERIALS: 316 stainless steel

CHAMBER TEMPERATURE: Factory preset

TEMPERATURE CONTROL: PID control

GAS CONNECTIONS: 1/4” stainless steel

SAMPLE FLOW: 3 litres/min

FILTER TYPE: Stainless steel sintered disk

AVERGAE FILTER PORE SIZE: 100 micron

CHANGEOVER VALVE: Heated ball valve

MAX INLET THC CONCENTRATION: 2000ppm propane equivalent

WARM UP TIME: Average 60 minutes

POWER: 240 Vac (650W )

WEIGHT: 6kg